This barrier is meant to keep moisture from getting to the insulation in the walls and ceilings and it is required by building codes when insulating most houses.
Install attic insulation vapor barrier.
Remove any transferable items from the attic so that they do not get in the way as you work.
A plastic vapor barrier is best installed in a vented attic within climates with over 8 000 heating degree days.
Not be trapped inside.
Adding a second vapor barrier could cause condensation to become trapped in the insulation between the two vapor barriers.
The best approach for a vented attic in a cold climate is installing a layer of drywall with a good coat of latex paint the paint creates a semi permeable vapor barrier.
If there is limited lighting find a way to provide more so you can see what you re doing.
Water vapor can pass through building materials in several ways including direct transmission and by heat transfer but studies suggest that fully 98 percent of the moisture transfer through walls occurs through air gaps including cracks around electrical fixtures and outlets and gaps along baseboards.
Some regions don t require a vapor barrier.
Vapor barriers are sheets of plastic or other material placed on one side of insulation sheets.
The paper creates a vapor barrier that helps keep the water vapor in the warm moist heated indoor air from migrating outward into the wall or other structure.
In any case the vapor barrier must point to the warm side.
If your climate does not meet these conditions a vapor retarder like latex ceiling paint will work well for your house if you are in all other climates except the hot dry and hot humid.
Attic insulation should always be installed with the paper backing facing toward the living space the ceiling in this case.
This acts as a barrier to keep heated moist air from rising up into the attic during cold weather.
The insulation fiberglass or cellulose is then placed on top of the drywall with no vapor barrier above or below.
Whether using loose fill or batts put the vapor barrier closest to the warm side of your installation where hot moist air would get in facing the house s interior in cold climates beneath floor insulation and the attic s interior in hot climates on top of floor insulation.
Vapor barriers in attics should only be installed on one side of the insulation.
Thus installing vapor barriers on wall surfaces must.
The purpose of insulation facing the facing on kraft faced insulation is made of kraft paper with an asphalt coating that makes the paper impermeable to water vapor.
Since some leakage of moisture into the insulation in inevitable murphy s law you want it to be able to freely escape from the insulation into the attic.