My salt system is a hayward goldline aquatrol t 5.
Hayward check system low salt.
No cell power low volts message diagnostics step 1a step 1b.
When the pump cycled back on the next day the same symptoms check salt check cell light on this time with no generating light on and reading 1600.
Here is how to recalibrate a hayward aqua rite turbo cell in three simple steps.
Aqua rite salt chlorinator has a built in reminder to inspect and clean the cell every 500 hrs.
Step 1 step 2 press the menu.
Remove the cell and clean per hayward s cleaning instructions pages 18 20.
Cleaned the cell it worked for a day.
Support center troubleshooting guides.
If the cell was reading a low salt level prior to cleaning the average salt may need to be reset.
Below we will cover what to do if check salt inspect cell light is flashing or on.
Every 500 operational hours this message will appear.
To reset the average salt level follow the steps outlined on pg 6 or wait 24 hours for the system to acclimate to the recent changes.
For detailed instructions on resetting the inspect cell message refer to pg.
First check the display salt reading if it s 2 700 ppm or lower the check salt light will come on.
We often get calls from people having a problem where their hayward aqua rite salt chlorinator system is reading a different salt level than manual testing.
If the check salt light is lit on a hayward aqua rite salt chlorinator it could mean a number of things.
My aquarite shows check salt check cell lights on reading was 700.
Hayward websites have been developed in compliance with standards for internet explorer 10 or later.
Clear inspect cell message follow these steps only if salt chlorination is enabled and the system shows a check system led with an inspect cell message.
Had the salt level checked by pool supply was 3200.
The system is not producing any chlorine and i completed every trouble shoot i can find.
Oh yeah salt pools still need to be shocked.
Often times pool owners can solve this by recalibrating the salt cell.
Before resetting inspect and or clean the cell if necessary.
However if your salt system has a light on or flashing we have additional resources for you.
While the examples to follow specifically showcase hayward salt systems the resources are applicable to other brands.
Low salt and check cell lights are on constantly even though a test of the water indicates that the salt level is within the normal range.
Thank you for your attention.
When diagnosing and repairing faults relating to high or low salt readings.